An ergonomic comparison of rowing machine designs: possible implications for safety

I A Bernstein, O Webber, R Woledge

UCL Institute of Human Performance, Royal National Orthopaedic Hospital Trust, Brockley Hill, Stanmore, Middlesex HA7 4LP, UK

Correspondence to:
Correspondence to:
Dr Bernstein, Gordon House Surgery, 78 Mattock Lane, London W13 0NZ, UK;
ibernstein{at} gordonhouse.freeserve.co.uk

Objectives: Ergometer training is a common cause of injuries in rowers. A randomised crossover study comparing two power head designs was carried out to examine ergonomic risk factors.

Methods: Six elite male rowers undertook 20 minute fatiguing rowing pieces with both fixed and floating power heads. A CODA MPX infrared telemetric motion analysis detector and the ergometer's interface were used to measure displacement, force, work performed, and power output.

Results: There was no significant difference in the total work performed, power per stroke, or metabolic load between the two ergometer designs. Fatigue was shown by a mean (SEM) fall of 9.7 (0.79) W/stroke (95% confidence interval (CI) 8.0 to 11.5) between minutes 8–10 and minutes 16–18 (p<0.001). The stroke length was 53 (13) mm (95% CI 18 to 89) longer with the fixed power head (p<0.02). With fatigue, the stroke with the fixed power head lengthened at the "catch" (beginning of the stroke) by 19.5 mm (p<0.01) and shortened at the finish of the stroke by 7.2 mm (p<0.05). No significant changes in stroke length were seen with the floating power head. The mean force per stroke was 12.1% (95% CI 3.0 to 21.2) (27.3 (8.0) N) higher with the power head fixed versus floating (p<0.02).

Conclusions: It is postulated that longer stroke lengths and greater forces are risk factors for soft tissue injuries. Further research into whether floating power head rowing ergometers are associated with lower injury rates than fixed power head designs is now needed.

Keywords: rowing; ergometry; fatigue; injury; motion analysis


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

 

The journal is co-owned by and the official journal of BASEM

Official journal of ECOSEP

Available online to all members of ACSP, AMSSM and SMNZ