ORIGINAL ARTICLE
High reproducibility of patellar tendon vascularity assessed by colour Doppler ultrasonography: a reliable measurement tool for quantifying tendon pathology
1 La Trobe University, Bundoora, Victoria, Australia
2 Monash University, Victoria, Australia
3 Medical Imaging Australia, Melbourne, Australia
4 La Trobe University Medical Centre, Medical Imaging, Victoria, Australia
Correspondence to:
Correspondence to:
Jill L Cook
La Trobe University, Bundoora, Victoria, Australia; j.cook{at}latrobe.edu.au
Background: This study examined whether patellar tendon vascularity could be quantified accurately in the clinical setting using colour Doppler ultrasonography.
Methods: A sonographer and two radiologists visually estimated tendon vascularity in millimetres in 74 tendons during ultrasound (US) examination and from hard copy films. These estimates were then compared to the length of vessels measured from the digital image in millimetres and the correlation between them was determined. A subset of 16 tendons was used to compare the estimates of vascularity by two examiners at US examination.
Results: The estimation of vascular length at US examination correlated highly with the measured vascular length (r = 0.92; 95% confidence interval (CI) 0.87 to 0.94), as did the length estimated from the films (r = 0.94; 95% CI 0.9 to 0.96). The correlation between examiners was 0.84 (95% CI 0.51 to 0.94) for the estimates made during US examination and 0.85 (95% CI 0.59 to 0.95) for the vessel lengths measured from the digital images.
Conclusions: These excellent correlations indicate that tendon vascularity can be reliably estimated using colour Doppler ultrasonography and tendon vascularity could therefore be used by clinicians to rate clinical change. This method of quantifying tendon vascularity could also be used in research to investigate the effects of tendon treatments on vascularity.
Abbreviations: CI, confidence interval; ICC, intraclass correlation coefficient; US, ultrasound
Keywords: Doppler ultrasound; measurement; patellar tendon; reliability; vascularity
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Sengkerij, P. M., de Vos, R.-J., Weir, A., van Weelde, B. J. G., Tol, J. L.
(2009). Interobserver Reliability of Neovascularization Score Using Power Doppler Ultrasonography in Midportion Achilles Tendinopathy. Am J Sports Med
37: 1627-1631
[Abstract] [Full Text] -
Malliaras, P., Richards, P. J., Garau, G., Maffulli, N.
(2008). Achilles Tendon Doppler Flow May Be Associated With Mechanical Loading Among Active Athletes. Am J Sports Med
36: 2210-2215
[Abstract] [Full Text] -
Fredberg, U., Bolvig, L., Andersen, N. T.
(2008). Prophylactic Training in Asymptomatic Soccer Players With Ultrasonographic Abnormalities in Achilles and Patellar Tendons: The Danish Super League Study. Am J Sports Med
36: 451-460
[Abstract] [Full Text] -
Gisslen, K., Gyulai, C., Nordstrom, P., Alfredson, H.
(2007). Normal clinical and ultrasound findings indicate a low risk to sustain jumper's knee patellar tendinopathy: a longitudinal study on Swedish elite junior volleyball players. Br. J. Sports. Med.
41: 253-258
[Abstract] [Full Text] -
Boesen, M. I., Boesen, A., Koenig, M. J., Bliddal, H., Torp-Pedersen, S.
(2006). Ultrasonographic Investigation of the Achilles Tendon in Elite Badminton Players Using Color Doppler. Am J Sports Med
34: 2013-2021
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.