© 2005 BMJ Publishing Group Ltd & British Association of Sport and Exercise Medicine
ORIGINAL ARTICLE
Enhancing the efficacy of the 20 m multistage shuttle run test
1 Faculty of Applied Health Sciences, Brock University, St Catherines, Ontario, Canada L2S 3AI
2 School of Sports, University of Wolverhampton, Wolverhampton, UK
3 Department of Sport and Exercise Science, University of Thessaly, Trikala, Greece
Correspondence to:
Correspondence to:
Yiannis Koutedakis
University of Thessaly, Department of Sport and Exercise Science, Karies, Trikala GR42100, Greece; y.koutedakis{at}uth.gr
Objective: Maximal oxygen uptake (Vo2max) of 44 ml kg1 min1 is an accepted criterion (Vo2CR) below which health and fitness for young male adults may be compromised. New algorithms validated for Vo2CR screening using the 20 m multistage shuttle run test (20mMST) were developed.
Methods: Vo2max was assessed in 110 males using a stationary gas analyser in a treadmill test (TT) and in 40 of these subjects using a portable gas analyser in the 20mMST. Vo2max predicted from the 20mMST in 70 subjects was used for cross validation. Two equations predicting Vo2max during 20mMST (EQMST) and TT (EQTT) were developed.
Results: Significant energy cost variance (ECV) was detected between TT and 20mMST (p<0.001), correlated significantly with subject height, and was a significant predictor of Vo2max differences between TT and 20mMST. The r2 of EQMST was 0.92 (p<0.001). Predicted Vo2max values from EQMST correlated with directly measured 20mMST Vo2max at r = 0.96 (p<0.001). ANOVA detected no mean difference (p>0.05) between predicted and measured values. Prevalence of low fitness based on Vo2CR was 0.37. McNemar
2 indicated significant differences in sensitivity (p<0.001) and specificity (p<0.05) between the original 20mMST equation (EQLÉG) and EQTT, regarding Vo2CR screening. Cohens
demonstrated higher agreement with TT Vo2max for EQTT (p<0.001) than EQLÉG (p<0.05). TT Vo2max correlated with the end result of both EQLÉG and EQTT at r = 0.75 (p<0.001). Unlike EQTT (p>0.05), mean predicted Vo2max from EQLÉG was significantly higher compared to TT Vo2max (p<0.001).
Conclusion: These algorithms increase the efficacy of 20mMST to accurately evaluate aspects of health and fitness.
Abbreviations: ANOVA, analysis of variance; CF, cardiorespiratory fitness; CI, confidence interval; CV, coefficient of variation; EC, energy cost; GEE, generalised estimating equations; GLM, general linear model; LIMAG, limits of agreement analysis; MAS, maximal attained speed; ROC, receiver operating characteristics; SD, standard deviation; TT, treadmill test; 20mMST, 20 m multistage shuttle run test
Keywords: energy cost; field testing; receiver operating characteristics; screening; Vo2max
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Flouris, A. D., Faught, B. E., Klentrou, P.
(2008). Cardiovascular disease risk in adolescent smokers: evidence of a `smoker lifestyle'. J Child Health Care
12: 221-231
[Abstract] -
Flouris, A. D, Canham, C. H, Faught, B. E, Klentrou, P.
(2007). Prevalence of cardiovascular disease risk in Ontario adolescents. Arch. Dis. Child.
92: 521-523
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.
