Register for email alerts and news feeds:
This journal | BMJ Group
rss
Published Online First: 28 June 2007. doi:10.1136/bjsm.2007.038570
British Journal of Sports Medicine 2008;42:295-299
Copyright © 2008 BMJ Publishing Group Ltd & British Association of Sport and Exercise Medicine.

ORIGINAL ARTICLES

Upper arm circumference is associated with race performance in ultra-endurance runners

B Knechtle1, P Knechtle1, I Schulze2 and G Kohler3

1 Gesundheitszentrum St Gallen, St Gallen, Switzerland
2 Deutschlandlauf, Horb-Nordstetten, Germany
3 Division of Biophysical Chemistry, Biozentrum, University of Basel, Basel, Switzerland

Correspondence to:
B Knechtle, Gesundheitszentrum St Gallen, Switzerland; beat.knechtle{at}hispeed.ch

Objective: To investigate the association of anthropometric parameters to race performance in ultra-endurance runners in a multistage ultra-endurance run.

Design: Descriptive field study.

Setting: The Deutschlandlauf 2006 race in Germany, where athletes had to run 1200 km within 17 consecutive days. There were no interventions.

Subjects: In total, there were 19 male Caucasian ultra-endurancerunners (mean (SD) 46.2 (9.6) years, 71.8 (5.2) kg, 179 (6) cm, BMI 22.5 (1.9) kg/m2).

Main outcome measurements: Determination of body mass, body height, length of lower limbs, skin-fold thicknesses, circumference of limbs, body mass index (BMI), percentage skeletal muscle mass (%SM), and percentage body fat (%BF) in 19 successful finishers in order to correlate anthropometric parameters with running performance.

Results: A significant association of upper arm circumference with the total running time was found (p<0.05, r2 = 0.26). No significant association was found with the directly measured anthropometric properties body height, body mass, average skin-fold thickness and the circumference of thigh and calf (p>0.05). Furthermore, no significant association was observed between the running time and the calculated parameters BMI, %BF, and %SM (p>0.05).

Conclusions: In an ultra-endurance run over 1200 km within 17 consecutive days, circumference of the upper arm was the only factor associated with performance in well-experienced ultra-endurance runners. Body mass, BMI, body height, length of limbs, skin-fold thicknesses, circumference of limbs and the calculated percentage body composition of skeletal muscle mass and body fat showed no association with running performance.

Keywords: body mass index; BMI; skeletal muscle mass; fat mass; stage race


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

Relevant Article

Commentary on "Upper arm circumference is associated with race performance in ultra-endurance runners"
Christoph Josef Raschka
Br. J. Sports Med. 2008 42: 299. [Extract] [Full Text] [PDF]

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

 

The journal is co-owned by and the official journal of BASEM

Official journal of ECOSEP

Available online to all members of ACSP, AMSSM and SMNZ