Register for email alerts and news feeds:
This journal | BMJ Group
rss
The most recent version of this article was published on 1 May 2008

Br J Sports Med. Published Online First: 10 December 2007. doi:10.1136/bjsm.2007.040709
Copyright © 2007 BMJ Publishing Group Ltd & British Association of Sport and Exercise Medicine.

Paper

Cervical muscle strength measurement is dependent on the location of thoracic support

Asghar - Rezasoltani 1*, Jari Ylinen 2, Amir-Hoshang Bakhtiari 3, Mona Norouzi 4 and Maryam Montazeri 4

1 Medical University of Shaheed Beheshti, Faculty of Rehabilitation, Damavand Ave., 16169 Tehran, Iran, Iran, Islamic Republic of
2 Jyvaskyla Central Hospital, Dept. of Physical and Rehabilitation Medicine,, Finland
3 Semnan University of Medical Sciences and Health Services, Faculty of Rehabilitation, Dept. of Phys, Iran, Islamic Republic of
4 Medical University of Shaheed Beheshti, Faculty of Rehabilitation, Iran, Islamic Republic of

* To whom correspondence should be addressed. E-mail: arezasoltani{at}yahoo.com.

Accepted 3 November 2007


Abstract

In all studies related to measuring the strength of neck extensor muscles the level of thoracic support has been adjusted differently. This may provide different results from different studies in which the level of lever arm has been set differently. Objective: The aim of this study was to measure and compare the isometric force and the isometric torque of neck extensor muscles at different levels of thoracic supports. Methods: Twenty healthy women volunteered in the study. The isometric force of neck extensor muscles was measured while the thoracic support was located at five different levels. The highest level was set at the level of spine of scapula (level I) and the other levels were located 2.5 cm lower from the previous one. The lowest level was set at 10 centimeter lower than the highest one. The isometric torque for each level was calculated from the multiplication of isometric force by the length of the lever arm measured from the upper tip of thoracic support to the center point of the cell load at the occiput. Results: The amount of isometric force and isometric torque of neck extensor muscles were increased step by step from 130.5, 138.9, 141.9, 147.9 to 155.4 N and from 33.7, 38.7, 42.5, 47.2 to 52.7 Nm respectively. Except for the isometric force of cervical extensor muscles measured at the level of II and III, the differences between the other levels were significant (P< 0.05). There was a high significant correlation between isometric force and isometric torque measurements of neck extensor muscles at different levels (0.81 < r < 0.96). Conclusion: In this study, by changing the length of lever arm, the isometric force and isometric torque measurements of neck extensor muscles were varied accordingly. Therefore, it is strongly recommended to set a certain level of thoracic support in follow up and interventional studies. To set the level of thoracic support at a certain level may provide the possibility to compare the strength of neck extensor muscles from different studies. The measurements at the level of spine of scapula appeared to be an easy method and less time consuming. Key Words – neck, isometric, force, torque, support

Key Words: neck, isometric, force, torque, support


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

 

The journal is co-owned by and the official journal of BASEM

Official journal of ECOSEP

Available online to all members of ACSP, AMSSM and SMNZ