High reproducibility of patellar tendon vascularity assessed by colour Doppler ultrasonography: a reliable measurement tool for quantifying tendon pathology
  1. J L Cook1,
  2. R Ptazsnik2,
  3. Z S Kiss3,
  4. P Malliaras1,
  5. M E Morris1,
  6. J De Luca4
  1. 1La Trobe University, Bundoora, Victoria, Australia
  2. 2Monash University, Victoria, Australia
  3. 3Medical Imaging Australia, Melbourne, Australia
  4. 4La Trobe University Medical Centre, Medical Imaging, Victoria, Australia
  1. Correspondence to:
 Jill L Cook
 La Trobe University, Bundoora, Victoria, Australia; j.cooklatrobe.edu.au

Abstract

Background: This study examined whether patellar tendon vascularity could be quantified accurately in the clinical setting using colour Doppler ultrasonography.

Methods: A sonographer and two radiologists visually estimated tendon vascularity in millimetres in 74 tendons during ultrasound (US) examination and from hard copy films. These estimates were then compared to the length of vessels measured from the digital image in millimetres and the correlation between them was determined. A subset of 16 tendons was used to compare the estimates of vascularity by two examiners at US examination.

Results: The estimation of vascular length at US examination correlated highly with the measured vascular length (r = 0.92; 95% confidence interval (CI) 0.87 to 0.94), as did the length estimated from the films (r = 0.94; 95% CI 0.9 to 0.96). The correlation between examiners was 0.84 (95% CI 0.51 to 0.94) for the estimates made during US examination and 0.85 (95% CI 0.59 to 0.95) for the vessel lengths measured from the digital images.

Conclusions: These excellent correlations indicate that tendon vascularity can be reliably estimated using colour Doppler ultrasonography and tendon vascularity could therefore be used by clinicians to rate clinical change. This method of quantifying tendon vascularity could also be used in research to investigate the effects of tendon treatments on vascularity.

  • CI, confidence interval
  • ICC, intraclass correlation coefficient
  • US, ultrasound
  • Doppler ultrasound
  • measurement
  • patellar tendon
  • reliability
  • vascularity