Abstract

Background: Increased knee valgus predicts the risk of anterior cruciate ligament (ACL) injury, particularly in women. Reducing injury rates thus relies on detecting and continually evaluating people with relatively large valgus motions.

Objectives: To examine the potential of a two dimensional (2D) video analysis method for screening for excessive valgus.

Methods: Ten female and 10 male National Collegiate Athletic Association basketball players had three dimensional (3D) knee valgus and two dimensional (2D) frontal plane knee angle quantified during side step, side jump, and shuttle run tasks. 3D valgus was quantified from external marker coordinates using standard techniques, and 2D data were obtained from both the frontal plane projections of these coordinates (2D-Mot) and manual digitisation of digital video footage (2D-Cam). A root mean square (RMS) error was calculated between 2D-Mot and 2D-Cam data to evaluate the reliability of the latter. Correlations between 2D-Cam and 3D data (intersubject and intrasubject) were also conducted, and regression slope and r2 values obtained.

Results: 2D-Cam and 2D-Mot data were consistent for side step (RMS  =  1.7°) and side jump (RMS  =  1.5°) movements. Between subjects, 2D-Cam and 3D data correlated well for the side step (r2  =  0.58) and side jump (r2  =  0.64). Within subjects, 2D-Cam and 3D data correlated moderately for the side step (r2  =  0.25 (0.19)) and side jump (r2  =  0.36 (0.27)).

Conclusions: The 2D-Cam method can be used to screen for excessive valgus in elite basketball players, particularly for movements occurring primarily in the frontal plane. This method may also be a useful training evaluation tool when large reductions in dynamic valgus motions are required.

Footnotes

  • Competing interests: none declared

  • Ethics approval: study approval was obtained through the institutional review board of the Cleveland Clinic Foundation, and written informed consent for all subjects was obtained.

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.