PT - JOURNAL ARTICLE AU - J P Buckley AU - J Sim AU - R G Eston AU - R Hession AU - R Fox TI - Reliability and validity of measures taken during the Chester step test to predict aerobic power and to prescribe aerobic exercise AID - 10.1136/bjsm.2003.005389 DP - 2004 Apr 01 TA - British Journal of Sports Medicine PG - 197--205 VI - 38 IP - 2 4099 - http://bjsm.bmj.com/content/38/2/197.short 4100 - http://bjsm.bmj.com/content/38/2/197.full SO - Br J Sports Med2004 Apr 01; 38 AB - Objectives: To evaluate the reliability and validity of measures taken during the Chester step test (CST) used to predict VO2max and prescribe subsequent exercise. Methods: The CST was performed twice on separate days by 7 males and 6 females aged 22.4 (SD 4.6) years. Heart rate (HR), ratings of perceived exertion (RPE), and oxygen uptake (VO2) were measured at each stage of the CST. Results: RPE, HR, and actual VO2 were the same at each stage for both trials but each of these measures was significantly different between CST stages (p<0.0005). Intertrial bias ±95% limits of agreement (95% LoA) of HR reached acceptable limits at CST stage IV (−2±10 beats/min) and for RPE at stages III (0.2±1.4) and IV (0.5±1.9). Age estimated HRmax significantly overestimated actual HRmax of 5 beats/min (p = 0.016) and the 95% LoA showed that this error could range from an underestimation of 17 beats/min to an overestimation of 7 beats/min. Estimated versus actual VO2 at each CST stage during both trials showed errors ranging between 11% and 19%. Trial 1 underestimated actual VO2max by 2.8 ml/kg/min (p = 0.006) and trial 2 by 1.6 ml/kg/min (not significant). The intertrial agreement in predicted VO2max was relatively narrow with a bias ±95% LoA of −0.8±3.7 ml/kg/min. The RPE and %HRmax (actual) correlation improved with a second trial. At all CST stages in trial 2 RPE:%HRmax coefficients were significant with the highest correlations at CST stages III (r = 0.78) and IV (r = 0.84). Conclusion: CST VO2max prediction validity is questioned but the CST is reliable on a test-retest basis. VO2max prediction error is due more to VO2 estimation error at each CST stage compared with error in age estimated HRmax. The HR/RPE relation at >50% VO2max reliably represents the recommended intensity for developing cardiorespiratory fitness, but only when a practice trial of the CST is first performed.