Skip to main content
Log in

Summary

A temperate environment heat tolerance test (HTT) was formerly reported (Shvartz et al. 1977b) to distinguish heat acclimatized humans from former heat stroke patients. The purpose of this investigation was to evaluate the ability of HTT to measure acute individual changes in the HR and Tre responses of normal subjects, induced by classical heat acclimation procedures, thereby assessing the utility and sensitivity of HTT as a heat tolerance screening procedure. On day 1, 14 healthy males performed HTT (23.2±0.5 ° C db, 14.9±0.5 ° C wb) by bench stepping (30 cm high, 27 steps · min-1) for 15 min at 67±3% \(\dot V_{O_{2\max } }\). On days 2–9, all subjects underwent heat acclimation (41.2±0.3 ° C db, 28.4±0.3° C wb) via treadmill exercise. Heat acclimation trials (identical on days 2 and 9) resulted in significant decreases in HR (170±3 vs 144±5 beats · min−1), Tre (39.21±0.09 vs 38.56±0.17 ° C), and ratings of perceived exertion; plasma volume expanded 5.2±1.7%. On day 10, subjects repeated HTT; day 1 vs day 10 HR were statistically similar (143±6 vs 137±6 beats · min−1, p>0.05) but Tre decreased significantly (37.7±0.1 vs 37.5±0.1 ° C, p<0.05). Group mean HTT composite score (day 1 vs day 10) was unchanged (63±5 vs 72±6, p>0.05), and individual composite scores indicated that HTT did not accurately measure HR and Tre trends at 41.2 ° C in 6 out of 14 subjects. Among the physical characteristics of subjects, only \(\dot V_{O_{2\max } }\) correlated significantly (r 2=0.74, p<0.001) with HTT, indicating a large aerobic component. We concluded that HTT is not a substitute for classical heat tolerance tests conducted at high ambient temperatures. HTT is apparently most useful in patient or at-risk populations in which preliminary or gross distinctions between heat tolerant and heat intolerant individuals are required.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Armstrong LE, Costill DL, Fink WJ, Bassett D, Hargreaves M, Nishibata I, King DS (1985) Effects of dietary sodium on body and muscle potassium content during heat acclimation. Eur J Applied Physiol 54:391–397

    Google Scholar 

  • Armstrong LE, Hubbard RW, DeLuca JP, Christensen EL (1986) Self-paced heat acclimation procedures. US Army Research Institute of Environmental Medicine, Heat Research Division, Natick, MA, Technical Report No. T8-86

    Google Scholar 

  • Bligh J, Johnson KG (1973) Glossary of terms for thermal physiology. J Appl Physiol 35:941–961

    Google Scholar 

  • Borg G (1970) Perceived exertion as an indicator of somatic stress. Scand J Rehabil Med 2:92–98

    Google Scholar 

  • Burch GE (1956) Influence of hot and humid environment on the patient with coronary heart disease. J Chronic Dis 4:350–363

    Google Scholar 

  • Dill DB, Costill DL (1974) Calculation of percentage changes in volumes of blood, plasma, and red cells in dehydration. J Appl Phyiol 37:247–248

    Google Scholar 

  • Dresoti AO (1935) Problems arising out of temperature and humidity in deep mining in the Witwatersrand. J Chem Metallurgical Mining Soc South Africa 36:102–129

    Google Scholar 

  • DuBois D, DuBois EF (1915) The measurement of the surface area of man. Arch. Int Med 15:868–881

    Google Scholar 

  • Epstein Y, Shapiro Y, Brill S (1983) Role of surface area-to-mass ratio and work efficiency in heat tolerance. J Appl Physiol 54:831–836

    Google Scholar 

  • Graichen H, Raschati R, Gonzalez RR (1982) Automatic dew point temperature sensor. J Appl Physiol 52:1658–1660

    Google Scholar 

  • Hausmann A, Baleyew D, Patigay J (1966) Selection criteria for rescue workers operating in hot atmospheres. Rev Inst Hyg Mines 21:36–48

    Google Scholar 

  • Kasch FW (1984) The validity of the Astrand and Sjostrand submaximal tests. Physic Sportsmed 12:47–52

    Google Scholar 

  • McArdle WB, Katch FI, Pechar GS (1973) Comparison of continuous and discontinuous treadmill and bicycle tests for 389-01. Med Sci Sports Exerc 5:156–160

    Google Scholar 

  • Robinson S, Wiley SL, Myhre LG, Bondurant S, Mamlin JJ (1976) Temperature regulation of men following heatstroke. Isr J Med Sci 12:786–795

    Google Scholar 

  • Shapiro Y, Magazanik A, Udassin R, Ben-Baruch G, Shvartz E, Shoenfeld Y (1979) Heat Intolerance in former heatstroke patients. Ann Int Med 90:913–916

    Google Scholar 

  • Shvartz E, Shapiro Y, Magazanik A, Meroz A, Birnfeld H, Mechtinger A, Shibolet S (1977a) Heat acclimation, physical fitness, and responses to exercise in temperate and hot environments. J Appl Physiol 43:678–683

    Google Scholar 

  • Shvartz E, Shibolet S, Meroz A, Magazanik A, Shapiro Y (1977b) Prediction of heat tolerance from heart rate and rectal temperature in a temperate environment. J Appl Physiol 43:684–688

    Google Scholar 

  • Strydom NB (1980) Heat intolerance: its detection and elimination in the mining industry. South African J Sci 76:154–156

    Google Scholar 

  • Strydom NB, Williams CG (1969) Effect of physical conditioning on the state of heat acclimatization of Bantu laborers. J Appl Physiol 27:262–265

    Google Scholar 

  • Wyndham CH (1973) The physiology of exercise under heat stress. Annu Rev Physiol 35:193–200

    Google Scholar 

  • Wyndham CH, Benade AJA, Williams CG, Strydom NB, Golden A, Heynes AJA (1968) Changes in central circulation and body fluid spaces during acclimatization to heat. J Appl Physiol 25:586–593

    Google Scholar 

  • Wyndham CH, Bouwer WM, Paterson HE, Devine MG (1953) Practical aspects of recent physiological studies in gold mines. J Chem Metallurg Mining Soc South Africa 7:287–313

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Armstrong, L.E., Hubbard, R.W., DeLuca, J.P. et al. Evaluation of a temperate environment test to predict heat tolerance. Europ. J. Appl. Physiol. 56, 384–389 (1987). https://doi.org/10.1007/BF00417764

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00417764

Key words

Navigation