Journal of Biomechanics

Volume 26, Issue 8, August 1993, Pages 969-990
Journal of Biomechanics

Hip joint loading during walking and running, measured in two patients

https://doi.org/10.1016/0021-9290(93)90058-MGet rights and content

Abstract

The resultant hip joint force, its orientation and the moments were measured in two patients during walking and running using telemetering total hip prostheses. One patient underwent bilateral joint replacement and a second patient, additionally suffering from a neuropathic disease and atactic gait patterns, received one instrumented hip implant. The joint loading was observed over the first 30 and 18 months, respectively, following implantation. In the first patient the median peak forces increased with the walking speed from about 280% of the patient's body weight (BW) at 1 km h−1 to approximately 480% BW at 5 km h−1. Jogging and very fast walking both raised the forces to about 550% BW; stumbling on one occasion caused magnitudes of 720% BW. In the second patient median forces at 3 km h−1 were about 410% BW and a force of 870% BW was observed during stumbling. During all types of activities, the direction of the peak force in the frontal plane changed only slightly when the force magnitude was high. Perpendicular to the long femoral axis, the peak force acted predominantly from medial to lateral. The component from ventral to dorsal increased at higher force magnitudes. In one hip in the first patient and in the second patient the direction of large forces approximated the average anteversion of the natural femur. The torsional moments around the stem of the implant were 40.3 Nm in the first patient and 24 Nm in the second.

References (54)

  • S. Backman

    The proximal end of the femur

    Acta Radiol.

    (1957)
  • G. Bergmann

    Ein Dreikomponenten-Kraftaufnehmer und seine Anwendung für die Messung von Gelenk-kräften am Tier

  • G. Bergmann et al.

    Long term animal test with instrumented hip implants

  • G. Bergmann et al.

    Instrumentation of a hip joint prosthesis

  • G. Bergmann et al.

    In vivo measurement of temperature rise in a hip implant

  • G. Bergmann et al.

    Loading of hip implants by torsional moments

  • G. Bergmann et al.

    Load reduction of hip joint implants by forearm crutches

  • G. Bergmann et al.

    The influence of floor materials on the hip joint loading

  • G. Bergmann et al.

    Die Messung von Gelenkkräften in vivo

  • G. Bergmann et al.

    Measurement of hip joint forces in sheep

  • G. Bergmann et al.

    Influence of orthotic devices on the forces at the hip joint

  • G. Bergmann et al.

    In vivo Messung der Hüftgelenkbelastung—1. Teil Krankengymnastik

    Z. Orthop.

    (1989)
  • G. Bergmann et al.

    In vivo hip joint force measurements in one patient

  • G. Bergmann et al.

    Hip joint forces during physical therapy after joint replacement

  • G. Bergmann et al.

    Measurement of spatial forces by the ‘Matrix’-method

  • G. Bergmann et al.

    A comparison of hip joint force in sheep, dog and man

    J. Biomechanics

    (1985)
  • R.A. Brand et al.

    Comparison of hip force calculations and measurements in the same patient

  • Cited by (1072)

    View all citing articles on Scopus
    View full text